61 Results
View Results:
Sort by:
Implementation of Experimental Wind Tunnel Data in RFEM
How we can introduce experimental wind tunnel data in RFEM?
Implementation of Experimental Wind Tunnel Data in RWIND
How we can introduce experimental data in RWIND?
Effective Section
Can I calculate the effective section properties of a cross-section using RSECTION?
Question
When determining the effective cross-section properties according to EN 1993‑1‑1, EN 1993‑1‑5, or EN 1999̩1‑1, SHAPE‑THIN displays a warning message saying that the effective widths are only determined for straight elements. What does this mean?
Tensile Membrane Structures
Which Dlubal programs do I need for tensile membrane structures?
- 005450
- RFEM 6
- RSTAB 9
-
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Aluminum Design for RFEM 6
- Aluminum Design for RSTAB 9
- Form-Finding for RFEM 6
- Steel Structures
- Aluminum and Lightweight Structures
- Temporary Structures
- Tensile Membrane Structures
- Structural Analysis & Design
- Form-Finding and Cutting Patterns
- Dynamic and Seismic Analysis
- Eurocode 3
- Eurocode 9
- ANSI/AISC 360
- ADM
Temporary Structures
I would like to analyze temporary structures. Which programs do you recommend?
Programs for Timber Structures
Which Dlubal Software programs can I use to calculate and design timber structures?
- 005437
- RFEM 6
- RSTAB 9
-
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Steel Joints for RFEM 6
- Torsional Warping (7 DOF) for RFEM 6
- Torsional Warping (7 DOF) for RSTAB 9
- Steel Structures
- Structural Analysis & Design
- Stress Analysis
- Stability Analysis
- Warping Torsion Analysis
- Steel Connections
- Cold-Formed Sections
- Eurocode 3
- ANSI/AISC 360
- CSA S16
- IS 800
- GB 50017
- SP 63.13330
- BS 5950-1
- AS 4100
- SIA 263
Programs for Steel Structures
Which programs and add-ons are suitable for the structural analysis and design of steel structures?
Cable and Tensile Structures
I would like to analyze cable and tensile structures. Is it possible to use RFEM or RSTAB for this?
Question
Is there a way to prepare an EC3 buckling check without setting the intermediate support manually, or is there a workaround that can speed this up?
AISC 341 Limit State Types
Which Limit State Types are applicable for the AISC 341 seismic design?
Question
For design, I need the load combinations from 1.00*G + 1.50*Q. How can I generate them automatically?
Question
What should be considered when using a failure of columns under tension in the RF‑/DYNAM Pro – Equivalent Loads add-on module?
Question
Are the models and presentations from Info Day 2019 freely available, and can you send them to me?
Question
Why does the web service show "ERROR: Map not found."?
CSA S16 Class 4 Sections
Can I design members with Class 4 sections according to CSA S16 in the Steel Design add-on?
Question
Why are the tolerance zones between the zone borders 5 km wide on the online snow load map of Austria?
RF-/STEEL Warping Torsion
For which programs is the STEEL Warping Torsion add-on module available?
Equivalent Round Section Dimension
How is the dimension for an equivalent round section calculated in the Timber Design add-on?
Question
How can I enter or read out a response spectrum via the COM interface in DYNAM Pro?
Question
Red values are displayed in the intermediate results of RF‑SOILIN. Why?
Imposed Loads with Stiffness Modifications
I have defined temperature loads, strain loads, or a precamber. Once I modify stiffnesses, the deformations are no longer plausible.
Question
Can RF‑STEEL AISC optimize cross-sections for serviceability?
Custom Sections for AISI Design
Can I design user-defined (parametric) sections according to AISI S100 or CSA S136?
Stability Design in RF-STEEL AISC
Why are my steel members not being designed for stability in RF-STEEL AISC?
- 004727
- RFEM 5
- RSTAB 8
-
- Concrete Structures
- Steel Structures
- Timber Structures
- Tensile Membrane Structures
- Structural Analysis & Design
- Finite Element Analysis
- Wind Simulation & Wind Load Generation
- Stability Analysis
- Dynamic and Seismic Analysis
- Form-Finding and Cutting Patterns
- Cold-Formed Sections
- Eurocode 1
- Eurocode 3
- Eurocode 5
Question
Are the models and presentations from Info Day 2020 freely available, and can you send them to me?
CSA S16 Class 4 Section
My section is classified as Class 4 and non-designable in RF-/STEEL CSA. However, my manual calculation shows a different class. Why the difference?
Question
I am performing a design in RF‑/STEEL AISC for result combinations from RF‑/DYNAM Pro and get the error message "Not designable - Null value of the critical moment on the segment". What should I do?
- 005113
- Timber Design for RFEM 6
- Timber Design for RSTAB 9
-
- Aluminum Design for RFEM 6
- Aluminum Design for RSTAB 9
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Stress-Strain Analysis for RFEM 6
- Stress-Strain Analysis for RSTAB 9
- Steel Joints for RFEM 6
- Timber Structures
- Concrete Structures
- Steel Structures
- Structural Analysis & Design
- Eurocode 2
- Eurocode 3
- Eurocode 5
- Eurocode 9