381 Results
View Results:
Sort by:
Considering Weld Eccentricity in RFEM 6
Is it possible to consider the eccentricity of unsymmetrical line welds for the stress analysis in RFEM 6?
Implementation of Experimental Wind Tunnel Data in RFEM
How can we introduce experimental wind tunnel data in RFEM?
Stability Analysis According to EN 1999-1-1
Is it possible to perform stability analysis according to EN 1999‑1‑1 in RSECTION 1?
Stability Analysis According to EN 1993-1-1
Is it possible to perform stability analysis according to EN 1993‑1‑1 in RSECTION 1?
Implementation of Experimental Wind Tunnel Data in RWIND
How can we introduce experimental data in RWIND?
Stiffeners at Girder Flanges of Rigid Frame Joint
How do the stiffeners on the outer flange edges of a rigid frame joint beam affect the maximum resistant moment as well as the rotational stiffness and the accompanying displacements of a frame structure?
Component-Based Finite Element Method (CBFEM) in RFEM 6
What is the component-based finite element method (CBFEM)?
Aluminum and Lightweight Structures
I would like to design an aluminum structure. Is it possible to use RFEM or RSTAB for this?
Question
When determining the effective cross-section properties according to EN 1993‑1‑1, EN 1993‑1‑5, or EN 1999̩1‑1, SHAPE‑THIN displays a warning message saying that the effective widths are only determined for straight elements. What does this mean?
Design of Hydraulic Steel Structures
Can I analyze and design hydraulic steel structures with the Dlubal programs?
Programs for Laminate and CLT Structures
Which programs do I need for laminate and sandwich structures, or cross-laminated timber (CLT)?
Stability Analysis of Structural Components with Asymmetric Cross-Section
Is it possible to use the General Method according to EN 1993‑1‑1, 6.3.4 to design structural components with an asymmetric cross-section in the Steel Design add-on for RFEM 6 or RSTAB 9?
Question
I get a message saying that the General Method is only allowed for I-sections, even though I do want to design an I-section. Why?
Add-ons for Concrete Structures
Which products do you recommend for the structural analysis and design of reinforced concrete structures?
Effective Section
Can I calculate the effective section properties of a cross-section using RSECTION?
Tensile Membrane Structures
Which Dlubal programs do I need for tensile membrane structures?
Pipe as Shear Key in RF-/JOINTS Steel – Column Base Add-on Module
How do I define a pipe as a shear key in RF‑/JOINTS Steel – Column Base add-on module?
- 005450
- RFEM 6
- RSTAB 9
-
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Aluminum Design for RFEM 6
- Aluminum Design for RSTAB 9
- Form-Finding for RFEM 6
- Steel Structures
- Aluminum and Lightweight Structures
- Temporary Structures
- Tensile Membrane Structures
- Structural Analysis & Design
- Form-Finding and Cutting Patterns
- Dynamic and Seismic Analysis
- Eurocode 3
- Eurocode 9
- ANSI/AISC 360
- ADM
Temporary Structures
I would like to analyze temporary structures. Which programs do you recommend?
Question
I am copying a design case and/or selecting a different or further node for the design. However, the connection geometry defined in the previous design case is not transferred. Why?
Question
What does the design information mean:
Geometry error left side:
End plate of the girder: Lambda2 >1.4
Column flange: Lambda2 >1.4
I cannot find an explanation in the manual or online.
Question
Why is it possible to switch off the individual design checks in RF‑/FOUNDATION Pro? After all, this poses a risk for the user to "accidentally" disable certain design checks and possibly design a foundation that is undersized?
- 005437
- RFEM 6
- RSTAB 9
-
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Steel Joints for RFEM 6
- Torsional Warping (7 DOF) for RFEM 6
- Torsional Warping (7 DOF) for RSTAB 9
- Steel Structures
- Structural Analysis & Design
- Stress Analysis
- Stability Analysis
- Warping Torsion Analysis
- Steel Connections
- Cold-Formed Sections
- Eurocode 3
- ANSI/AISC 360
- CSA S16
- IS 800
- GB 50017
- SP 63.13330
- BS 5950-1
- AS 4100
- SIA 263