19 Results
View results:
Sort by:
Instability
My model is unstable. What could be the reason?
Instability
My model is unstable. What could be the reason?
Member Design Supports for Deflection Checks
How do I define a member as a cantilever and not as supported at both ends for serviceability or deflection design?
Line Hinge of Slab-Wall Connection
I would like to connect my masonry wall to a reinforced concrete slab. What is the best way to create a line hinge?
AISC 360-16 Shear Plane in Thread Option
Can I exclude bolt threads from the shear planes according to AISC 360-16 in the Steel Joints Add-on?
Unstable Model - Troubleshooting
My model in RFEM 6 / RSTAB 9 is unstable. How can I fix it?
Splice Connection
How do I create a splice connection in the Steel Joints add-on?
Instability when Using Building Model with "Rigid Diaphragm"
I have a 3D model and try to split it up into "walls" and "surfaces" with the Building Model and to calculate them separately. However, my structural system becomes unstable then. What can be the reason?
Surface Type Error
I received an error message “Surface of incompatible type... (Surface in upper plane of building story must be of ‘Load transfer’ type)” when running the calculation. What is the reason?
- 005113
- Timber Design for RFEM 6
- Timber Design for RSTAB 9
-
- Aluminum Design for RFEM 6
- Aluminum Design for RSTAB 9
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Stress-Strain Analysis for RFEM 6
- Stress-Strain Analysis for RSTAB 9
- Steel Joints for RFEM 6
- Timber Structures
- Concrete Structures
- Steel Structures
- Structural Analysis & Design
- Eurocode 2
- Eurocode 3
- Eurocode 5
- Eurocode 9
Materials of National Annexes
Where can I find the materials for the corresponding National Annexes in RFEM 6 and RSTAB 9?
Orthotropy Direction for Layers
Why cannot I define a rotation when defining layers?
Equivalent Round Section Dimension
How is the dimension for an equivalent round section calculated in the Timber Design add-on?
Stability Analysis with Incrementally Increasing Loading
Can I incrementally increase the load in RFEM 6 or RSTAB 9?
Setting of I-Beam Flange Support for Design in Structure Stability Add-on
In the Steel Design add-on, I have set the boundary conditions in such a way that the I-beam flange is restrained against the horizontal displacement. I then calculated the critical load factors using the Structure Stability add-on, but with no effect on the critical load factor value. What is the reason for this?
- 005437
- RFEM 6
- RSTAB 9
-
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Steel Joints for RFEM 6
- Torsional Warping (7 DOF) for RFEM 6
- Torsional Warping (7 DOF) for RSTAB 9
- Steel Structures
- Structural Analysis & Design
- Stress Analysis
- Stability Analysis
- Warping Torsion Analysis
- Steel Connections
- Cold-Formed Sections
- Eurocode 3
- ANSI/AISC 360
- CSA S16
- IS 800
- GB 50017
- SP 63.13330
- BS 5950-1
- AS 4100
- SIA 263