24 Results
View Results:
Sort by:
- 005113
- Timber Design for RFEM 6
- Timber Design for RSTAB 9
-
- Aluminum Design for RFEM 6
- Aluminum Design for RSTAB 9
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Stress-Strain Analysis for RFEM 6
- Stress-Strain Analysis for RSTAB 9
- Steel Joints for RFEM 6
- Timber Structures
- Concrete Structures
- Steel Structures
- Structural Analysis & Design
- Eurocode 2
- Eurocode 3
- Eurocode 5
- Eurocode 9
Materials of National Annexes
Where can I find the materials for the corresponding National Annexes in RFEM 6 and RSTAB 9?
Modal Analysis
How can I display mode shapes in RFEM 6 and RSTAB 9?
Response Spectrum Analysis
How can I perform an earthquake analysis in RFEM 6 and RSTAB 9?
Modal Analysis - Minimum Initial Strain
Why do the results in a modal analysis differ between the initial prestress and the surface load?
Neglecting Masses in RFEM 6 / RSTAB 9
How can I neglect masses in my modal analysis in RFEM 6 / RSTAB 9?
Normalization of Mode Shape
Where can I adjust the normalization of a mode shape in RFEM 6 / RSTAB 9?
Column Failure Modal Analysis
How can I analyze the failure of an object, such as a column, in my modal analysis?
Line Hinge of Slab-Wall Connection
I would like to connect my masonry wall to a reinforced concrete slab. What is the best way to create a line hinge?
Member Design Supports for Deflection Checks
How do I define a member as a cantilever and not as supported at both ends for serviceability or deflection design?
Strength of Weld-Affected Zone for Aluminum
How do I consider the strength of weld-affected zone for aluminum?
Exclude Lateral Torsional Buckling Check
My beam has a continuous lateral support and therefore lateral torsional buckling (LTB) is not a concern. How do I define the effective length?
AISC 360-16 Shear Plane in Thread Option
Can I exclude bolt threads from the shear planes according to AISC 360-16 in the Steel Joints Add-on?
Splice Connection
How do I create a splice connection in the Steel Joints add-on?
Instability when Using Building Model with "Rigid Diaphragm"
I have a 3D model and try to split it up into "walls" and "surfaces" with the Building Model and to calculate them separately. However, my structural system becomes unstable then. What can be the reason?
- 005437
- RFEM 6
- RSTAB 9
-
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Steel Joints for RFEM 6
- Torsional Warping (7 DOF) for RFEM 6
- Torsional Warping (7 DOF) for RSTAB 9
- Steel Structures
- Structural Analysis & Design
- Stress Analysis
- Stability Analysis
- Warping Torsion Analysis
- Steel Connections
- Cold-Formed Sections
- Eurocode 3
- ANSI/AISC 360
- CSA S16
- IS 800
- GB 50017
- SP 63.13330
- BS 5950-1
- AS 4100
- SIA 263
Programs for Steel Structures
Which programs and add-ons are suitable for the structural analysis and design of steel structures?
Cable and Tensile Structures
I would like to analyze cable and tensile structures. Is it possible to use RFEM or RSTAB for this?
Tensile Membrane Structures
Which Dlubal programs do I need for tensile membrane structures?
Aluminum and Lightweight Structures
I would like to design an aluminum structure. Is it possible to use RFEM or RSTAB for this?
- 005450
- RFEM 6
- RSTAB 9
-
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Aluminum Design for RFEM 6
- Aluminum Design for RSTAB 9
- Form-Finding for RFEM 6
- Steel Structures
- Aluminum and Lightweight Structures
- Temporary Structures
- Tensile Membrane Structures
- Structural Analysis & Design
- Form-Finding and Cutting Patterns
- Dynamic and Seismic Analysis
- Eurocode 3
- Eurocode 9
- ANSI/AISC 360
- ADM