How can I correct the Error No. 1602 referring to a missing line input in a member definition?

Answer

The model input in RFEM is organized hierarchically. The basic element called 'Member' can not be defined directly, but is based on a hierarchically defined set of geometrical and physical definitions.


The error message No. 1602 appears if at least one member definition in the model has no assigned line input. 



In this case, the missing line input must be added to the affected member definitions or the invalid member definition must be deleted.