Question

Where can I specify a basic reinforcement with the details of a diameter and rebar spacing in RF‑CONCRETE Surfaces?


Answer:
You can find the provided basic reinforcement for reinforced concrete surfaces by specifying a rebar spacing and rebar diameter in Window 1.4 of RF‑CONCRETE Surfaces under the "Longitudinal Reinforcement" tab.


If you enter a diameter and a distance, the program automatically determines the reinforcement content [cm²/m].


Click the "OK" button to import this value.