46 Results
View Results:
Sort by:
Aluminum and Lightweight Structures
I would like to design an aluminum structure. Is it possible to use RFEM or RSTAB for this?
Effective Section
Can I calculate the effective section properties of a cross-section using RSECTION?
Programs for Laminate and CLT Structures
Which programs do I need for laminate and sandwich structures, or cross-laminated timber (CLT)?
Scaffolding and Rack Structures
We are looking for a program for scaffolding and rack structures. Is Dlubal Software suitable for this?
Question
When determining the effective cross-section properties according to EN 1993‑1‑1, EN 1993‑1‑5, or EN 1999̩1‑1, SHAPE‑THIN displays a warning message saying that the effective widths are only determined for straight elements. What does this mean?
- 005437
- RFEM 6
- RSTAB 9
-
- Steel Design for RFEM 6
- Steel Design for RSTAB 9
- Steel Joints for RFEM 6
- Torsional Warping (7 DOF) for RFEM 6
- Torsional Warping (7 DOF) for RSTAB 9
- Steel Structures
- Structural Analysis & Design
- Stress Analysis
- Stability Analysis
- Warping Torsion Analysis
- Steel Connections
- Cold-Formed Sections
- Eurocode 3
- ANSI/AISC 360
- CSA S16
- IS 800
- GB 50017
- SP 63.13330
- BS 5950-1
- AS 4100
- SIA 263
Programs for Steel Structures
Which programs and add-ons are suitable for the structural analysis and design of steel structures?
Question
Is there a way to prepare an EC3 buckling check without setting the intermediate support manually, or is there a workaround that can speed this up?
Question
Is it possible to display more values for the stress distribution over the layers in RF‑LAMINATE?
Question
Are the models and presentations from Info Day 2019 freely available, and can you send them to me?
Question
There is a note in the RF‑/JOINTS Timber - Steel to Timber add-on module saying that the member length is too short. What is the minimum length, and how can I avoid the problem?
Question
After the design was performed using RF‑/TIMBER Pro, I optimized a cross-section. Why is the utilization of the optimized cross-section exceeded now?
Question
Can I rotate a foundation about the Z-axis in the RF‑FOUNDATION Pro add-on module?
Orthotropy Direction for Layers
Why cannot I define a rotation when defining layers?
RF-/STEEL Warping Torsion
For which programs is the STEEL Warping Torsion add-on module available?
Question
Why it is not possible to design a biaxial bending with the RF‑/JOINTS add-on module?
Question
I have performed a buckling analysis in RF‑ALUMINUM. Where can I find the parameters used for the design in the add-on module?
Question
Where can I adjust the effective length lef according to Table 6.1 of Eurocode 5 in the TIMBER Pro add-on module?
Language Setting for RX-TIMBER
How can I change the language in the RX‑TIMBER add-on module?
Question
Red values are displayed in the intermediate results of RF‑SOILIN. Why?
Question
Can RF‑TIMBER AWC optimize cross-sections for fire design?
Question
How many members can be connected to a node in RF‑/JOINTS Timber - Steel to Timber, and what is the minimum angle between the members?
Timber Joints According to EN 1995-1-1, Section 8.2.2
Is it possible to use the JOINTS add-on module to design timber-to-timber connections according to EN 1995‑1‑1, Chapter 8.2.2, in RFEM 5 and RSTAB 8?
- 004727
- RFEM 5
- RSTAB 8
-
- Concrete Structures
- Steel Structures
- Timber Structures
- Tensile Membrane Structures
- Structural Analysis & Design
- Finite Element Analysis
- Wind Simulation & Wind Load Generation
- Stability Analysis
- Dynamic and Seismic Analysis
- Form-Finding and Cutting Patterns
- Cold-Formed Sections
- Eurocode 1
- Eurocode 3
- Eurocode 5