2440x
000501
2021-02-02

Non-Continuous Weld Seams

When using interrupted welds between the rail and flange, make sure that the applied weld length does not exceed the length of the rigid load application of the wheel load according to Equation 6.1 in [1].

If this is the case, the length of the rigid load transmission becomes governing for the design of the weld seams. No difference in the design ratio arises in the weld seam design compared to the use of the continuous rail weld seams.


Links
References
  1. EC 3. (2009). Eurocode 3: Design of Steel Structures - Part 6: Crane Supporting Structures; EN 1993-6:2007 + AC:2009
Downloads