471 Results
View Results:
Sort by:
Modeling of Timber-Concrete Composite Floor
How can I model a timber-concrete composite floor?
Question
The design criterion for VEd/VRd,c is displayed as governing, although there should be a shear reinforcement designed. Also, the design of VEd/VRds is missing. Why?
Question
How do I determine wind loads on structures of any shape?
Question
Is it possible to design a model with a pile foundation in RFEM?
Question
How many mode shapes do I need to consider in the dynamic analysis?
Online Authorization of RWIND with Software Key
How can I authorize the RWIND Simulation program online with a software key on a single‑user computer?
Question
How do I determine the stiffness center of my structural system?
Seismic Analysis
What is the approach for seismic design in RFEM or RSTAB 8?
Question
Why is the cracking moment Mcr smaller for biaxial bending than for uniaxial bending?
Question
In RF‑CONCRETE Surfaces, I get non-designable situations at some locations. Note 5 is displayed: "Allowable compressive stress of concrete in strut direction exceeded."
Question
Can I also use the wind load generator for open buildings?
Question
Why do I get such a small amount of reinforcement for the upstand beam? The amount of reinforcement for the downstand beams is significantly larger.
Question
How can I generate load combinations automatically in an existing file retroactively?
Question
How can I apply wind load distribution to a cylinder according to EN 1991‑4, Section 7.9?
Question
The building I am calculating is located in the North German Plain. How can I consider the increased snow load?
Bending Design of Block Foundations
How is the static depth d calculated in the bending design of block foundations (calculation as equivalent beams)?
Question
How can I calculate a timber-concrete composite floor with cross-laminated timber?
Question
The online service "Snow Load, Wind Speed, and Seismic Load Maps" displays the snow load zones 1*, 1a*, 2*, and 3* for Germany. Where are these snow load zones defined?
Question
What are the stiffness reduction factors k33 and k88 in the Multilayer Surfaces Add-on?
Question
Is it possible to design bidirectional ribbed plates, unidirectional ribbed plates, or hollow core slabs in RFEM?
Question
How can I change the colors of the graphical display of a reinforcement?
Question
What is the formula used to calculate the ASCE 7 wind velocity profile?
Question
Why is it not possible to select "ULS", "SLS", or "ULS/SLS" for the "required reinforcement"? I can no longer find the selection for this.
Question
We want to reinforce a floor slab of a round vessel radially or tangentially.Is there a way to calculate not an orthogonal reinforcement, but a radial or tangential reinforcement?
- 003312
- CONCRETE 8
- ALUMINUM 8
-
- CONCRETE Columns 8
- EC2 for RFEM 5
- EC2 for RSTAB 8
- TIMBER Pro 8
- CRANEWAY 8
- RF-CONCRETE Columns 5
- RF-CONCRETE 5
- RF-PLATE-BUCKLING 5
- RF-FOUNDATION Pro 5
- RF-HSS 5
- RF-GLASS 5
- RF-TIMBER Pro 5
- RF-SOILIN 5
- RF-FRAME-JOINT Pro 5
- RF-STEEL EC3 5
- RF-PUNCH Pro 5
- Eurocode 2
- Eurocode 3
- Eurocode 5
- Eurocode 9
- Eurocode 7