768x
000464
2024-01-10

Decisive Results

In these result tables, you can display the governing design results and their associated internal forces. Various sortings are available for this (by members or member sets and member or member set ends).

The tables initially show all available designs at the corresponding location. For this purpose, the internal forces that lead to the maximum utilization in the respective design are displayed. If you only want to display the internal forces associated with the governing design at a location, you can select 'Max' for the utilization in the result filter.

The internal forces of the governing designs at the member or member set ends can, for example, provide a reference for the connection design as to which load combination could be governing at this location.

In the result table manager, further filter options are available to you, for example, by limit state (ultimate limit state or serviceability limit state) and design type (cross-section check or stability analysis).