4775x
000095
2019-01-28
N

Node of Punching Shear

The design of punching shear or punching shear resistance can be performed according to EN 1992‑1‑1, 6.4, for example. In this case, the design of punching shear resistance is performed on this node without the punching shear reinforcement (6.4.4) or with punching shear reinforcement (6.4.5).

Depending on the geometry of the node of punching shear, the design is performed on a column or on a wall corner or a wall end.


Links
References
  1. European Committee for Standardization (CEN). (2010). Eurocode 2: Design of Concrete Structures – Part 1‑1: General Rules and Rules for Buildings, EN 1992‑1‑1:2004 + AC:2010.