Minimum reinforcement

IBC 2021 / ACI 318-19 (LRFD): Minimum reinforcement

Purpose of check

The minimum reinforcement check verifies whether the existing longitudinal reinforcement meets the minimum reinforcement for foundation slabs required by ACI 318-19. The check is performed separately for both foundation directions (x and y).

Determination of minimum reinforcement

The minimum reinforcement is determined according to ACI 318-19, 7.6.1.1 and 8.6.1.1:

The governing required reinforcement area results from the larger value of the statically required reinforcement As,stat (see bending design) and the minimum reinforcement:

Check/Utilization ratio

Software configuration

The existing reinforcement is taken from the defined foundation parameters, and the associated material properties are taken from the assigned concrete and reinforcement materials. The statically required reinforcement and the minimum reinforcement are automatically determined for each reinforcement layer and each design section.