5695x
006106
2026-02-10

Main

The Base tab manages the elementary member parameters. If you tick a check box in the 'Options' section, another dialog tab is usually added. There, you can define the respective details.

Member Type

The member type controls the way in which internal forces can be absorbed or which properties are assumed for the member. The list offers various member types to choose from.

Beam Member

A beam is a rigid bending member that can transfer all internal forces. A beam member has no hinges at its member ends. This member type can be loaded by all load types.

Rigid Member

A rigid member couples the displacements of two nodes through a rigid connection. It therefore basically corresponds to a coupling. This allows you to define members with very high stiffness, taking hinges into account that can also have spring constants and nonlinearities. Hardly any numerical problems occur because the stiffnesses are adapted to the system.

Internal forces are output for rigid members if you activate Results for couplings in the Navigator - Results at the bottom in the 'Members' category.

The following stiffnesses are applied for rigid members:

Longitudinal stiffness E · A 1013 · ℓ [SI unit] with ℓ = member length
Torsional rigidity G · IT 1013 · ℓ [SI unit]
Bending stiffness E · I 1013 · ℓ3 [SI unit]
Shear stiffness GAy / GAz (if activated) 1016 · ℓ3 [SI unit]

Info

These stiffness assumptions also apply to members of the coupling type.

Rib Member

Ribs can be used to model T-beams (downstand beams). For this member type, the eccentricities and effective plate widths are taken into account in the FEM model.

Ribs are primarily suitable for reinforced concrete members, since the rib internal forces and cross-sections are included in the Concrete Design. A steel plate with a welded-on "rib" should be modeled as a surface with an eccentrically connected member.

The 'Rib arrangement' list offers several options.

As a rule, a rib is an eccentrically arranged member. The eccentricity is automatically determined from half of the surface thickness and half of the member height. However, it can also be defined manually. The eccentricity of the rib increases the stiffness of the model. With a centric arrangement, the centroidal axis of the rib lies in the middle of the surface.

The effective widths of the rib are to be defined in the 'Flange dimensions' section for the left and right sides. In most cases, the 'Find automatically' setting can be retained, with which the program determines the two surfaces. If more than two surfaces meet at the line of the rib member, the governing surfaces must be defined manually.

There are various options for entering the integration widths b-y,int and b+y,int (see image New rib): The widths can be entered directly or automatically determined from the member length using the options Lref / 6 and Lref / 8. They can also be determined according to the specifications of a standard, for example according to 'EC2' section 5.3.2.1.

The by,int values define the width of the surface or of the catchment area from which the internal forces are to be integrated. The by,eff values represent the cross-section width of the rib flange from the web center to the respective edge. By default, by,int and by,eff are set equal. However, after clicking the Synchronizing button, you can define them separately.

If nodes of the 'Nodes on member' type have been defined, the rib can be defined section by section for the individual segments. If several segments are defined, the staggered width ranges can be linearized and connected with each other via the 'Linear Distribution' table column in order to prevent large stiffness jumps in the rib member.

For 3D models, the effective widths have no influence on the stiffness, since the increased stiffness is taken into account by the eccentric member. However, the effective widths affect the distribution of the member and surface internal forces.

Truss Member

A truss member corresponds to a beam member with moment hinges at both ends. Additionally, the rotation about the longitudinal axis is released at the member start by a hinge φx. For this member type, bending and torsional moments are output from the member loads.

Truss Member (Only N)

This type of truss member with the stiffness E ⋅ A is able to absorb axial forces in the form of tension and compression. Only nodal internal forces are output. The member has a linear internal force diagram unless a concentrated load acts on the member. No moment diagram is output that could result from self-weight or a line load. However, the nodal forces are calculated from the member loads, which ensures the correct transfer.

Info

For a 'truss member (only N)', no evasion perpendicular to the principal axes is possible. Member buckling effects are therefore not taken into account.

Tip

The difference between the 'Truss member' and 'Truss member (only N)' member types is explained in a webinar using an example.

Buckling-Restrained Brace

The buckling-restrained brace type enables the modeling of a member with a steel core (flat bar or cruciform cross-section) and a concrete-filled coating in a square or round hollow section. It is used especially in the USA for the stiffening of buildings endangered by earthquakes.

Info

The modeling is only possible for certain cross-section series to which the material type 'Buckling-restrained brace' is assigned (see the technical article Buckling-Restrained Brace on the right).

The steel core is movable in the concrete coating without bonding. Under compressive stress, a "micro-buckling" with high mode shapes occurs, since the coating prevents global buckling of the entire member.

Only the steel core is taken into account for the stiffness of the member; for the automatic self-weight, the concrete coating with the outer steel shell is also taken into account.

Tension Member

A tension member can only absorb tensile forces. The member type corresponds to a 'truss member (only N)' that fails under a compressive force.

The calculation of a truss work with tension members is iterative: In the first step, the internal forces of all members are determined. If tension members receive a negative axial force (compression), another iteration step starts. The stiffness components of these members are no longer taken into account – they have failed. This process is continued until no tension member fails anymore. A system can become unstable due to the failure of tension members.

Info

A failed tension member is again taken into account in the stiffness matrix if it receives tensile forces in a later iteration step due to redistribution effects (see chapter Analysis settings).

Compression Member

A compression member can only absorb compressive forces. The member type corresponds to a 'truss member (only N)' that fails under a tensile force. Failing compression members can lead to an unstable system.

Buckling Member

A buckling member corresponds to a 'truss member (only N)' that absorbs tensile forces without limit, but compressive forces only until the critical force is reached. For the Euler buckling mode 2, this force is determined as follows:

With this member type, instabilities that occur in a nonlinear calculation according to second-order or large deformation analysis due to the buckling of truss members can often be avoided. If these are replaced (realistically) by buckling members, in many cases the critical load is increased.

Cable Member

A cable can only be stressed in tension. This allows cable chains to be captured by an iterative calculation according to large deformation analysis, taking longitudinal and transversal forces into account.

Cables are suitable for models in which large deformations with corresponding changes in internal forces can occur. For simple guy wires such as for a canopy, tension members are completely sufficient.

Reinforcement Bar

With this member type, plain steel reinforcements can be modeled in the FE model of a reinforced concrete element. For example, discontinuity regions based on the truss analogy (tie and compression strut in corbels, beams with openings) can be analyzed.

The reinforcement bar has an automatic connection function to other elements such as members or surfaces if it is physically located within the element. Like the truss member (only N), a reinforcement bar only has a tangential stiffness. A nonlinear material behavior is currently not yet possible.

Important

This member type cannot be designed with the Concrete Design add-on.

In the 'Settings' section, a plain reinforcement is set as the member type. Further reinforcement bar types are available if the Tendons add-on is activated.

In the 'Master objects' section, assign the members or surfaces in which the reinforcement bar is located. Use the Multiple Selection button for this. Then, with the Select Automatically button, you can automatically connect the reinforcement bar to the master object.

Tip

For the master objects, it is recommended to use a nonlinear material (for example, damage).

Cable on Pulleys

This cable member type also only absorbs tensile forces and is calculated according to cable theory (large deformation analysis). However, a cable member on pulleys can only be defined on a polyline that lies in a plane and has at least three nodes. This member type is suitable for flexible tension elements whose longitudinal forces are guided through the model via deflection points. An application example is a pulley system.

In contrast to a normal cable member, only a displacement in the inner nodes in the longitudinal direction (ux) is possible. Therefore, the member must not be loaded by member loads that act in the local y or z direction. Only displacements ux and axial forces N are taken into account.

At the inner nodes of the polyline, it does not matter whether a nodal support is present or whether the member is connected to another structure: The overall system of the cable member is analyzed over the length of the polyline.

In the 'Pulleys' tab, you can define the further parameters such as deflection nodes and the properties of the pulley wheels.

The table allows you to arrange pulleys on one or more nodes of the cable. The 'Generate at nodes' list contains all nodes that are used when defining the polyline. In the 'Pulley wheel' column, you can select an already defined type for pulleys or define a new one.

From these specifications, the program generates nodes on the edge of the pulley wheel, cable members to these nodes, as well as rigid members to connect to the node of the polyline.

Result Beam

The result beam is suitable for integrating surface, solid, or member results in a fictitious member. For example, the resulting shear forces of a surface can be read for the masonry design.

The line of a result beam can be placed anywhere in the model. The result beam requires neither a support nor a connection to the model. However, a cross-section must be assigned to enable a design. No loads can be applied to a result beam.

Info

The cross-section of the result beam has no influence on the system stiffness.

In the 'Integrate stresses and forces' section, select the type of the result beam to define the geometric shape of the integration area. In the 'Parameters' section, you can then define the dimensions. They are related to the line of the member at its centroid.

In the 'Include objects' section, define the surfaces, surface cells, solids, and members whose results are to be taken into account in the integration. Alternatively, select 'All' objects and then exclude certain elements in the 'Excluded from inclusive objects' section.

Result Line

The result line is suitable for integrating surface, solid, or member results in a line. This line can be placed anywhere in the model.

The principle corresponds to a result beam. However, you do not need to assign a cross-section. In the 'Cross-section' tab, you can read the length of the line and, if necessary, rotate the line for the result display; it has no further function.

Load Transfer

With this member type, loads can be applied to objects that are connected to the member at end or intermediate nodes. The member itself has no stiffness. You can define the criteria for the load transfer in a new tab.

The load transfer is currently carried out with the strip method. The loading of the load transfer member – member load or nodal load of the type force, moment, or mass – is transferred proportionally to the closest common structural objects. These are, for example, supported nodes, members, nodes of surfaces, or supported lines.

If the self-weight of the member is to be taken into account, you can define the member weight in the 'Parameters' section.

In the 'Loaded objects' section, the numbers of the nodes are specified at which the member load is transferred to the adjacent objects. If not all of these nodes are relevant, you can exclude certain nodes in the 'Without effect on' section.

Virtual Joist

This member type allows you to apply the cross-section properties for Open Web Steel Joists that the Steel Joist Institute has stored in so-called "Virtual Joist" tables. These virtual joist cross-sections represent equivalent wide flange beams that come very close to the beam flange surface, the effective moment of inertia, and the weight. The girder is thus replaced by a member with a virtual cross-section. This allows complex load-bearing units such as a truss girder to be simulated in the overall system.

Select the 'series' of the virtual joist in the list.

In the 'Virtual joist' list, you can then define the exact type.

The Joist button in the 'Cross-section and material' section allows you to import the virtual joist from the cross-section library.

Composite Beam

With this member type, individual partial cross-sections can be modeled as separate members and connected with each other via rigid couplings. The composite behavior can be modeled as shear-rigid, shear-soft, or flexible. A corresponding fastener library is planned for a future extension.

The definition of the composite cross-section is currently carried out exclusively in RSECTION (see chapter Base of the RSECTION manual). The composite cross-sections already contained in the cross-section library will be transferred to the new concept at a later point in time and will thus also be usable. A uniform workflow is also planned for the design of the individual partial cross-sections in the future. However, the partial cross-sections can already be verified in the associated design add-ons.

Surface Model

This member type is primarily suitable for modeling castellated beams with openings or local cross-section reductions such as openings for supply lines in the member model. The member is converted into a surface model in which the member openings are arranged according to user specifications. However, the member is retained. The following prerequisites must be met:

  • The cross-section is a standardized or parametrized thin-walled cross-section with a web.
  • The material of the cross-section is based on an isotropic linear-elastic material model.

For the 'Surface model' member type, the member exists both as a member and as a surface object. The geometric properties are identical; both models have the same centroid. The display is controlled in the Navigator - Display via the entry Model → Basic objects → Members → Surface model or via the Surface Model button in the toolbar.

The FE mesh of the surface model is generated automatically; it currently cannot be influenced. The surface model is used in the static calculation. Both the member results (as with a result beam, where the stresses of the member partial surfaces are integrated into member internal forces) and the surface results are then available for evaluation. The control can also be carried out here via the Navigator - Display or the Surface Model button.

The design of a surface model member in the add-ons is carried out with the member internal forces and the member cross-section.

As can be seen in the image above, several rigid members are created at the member ends of a surface model member. They connect the surface model to the end nodes of the adjacent members. This ensures the correct transfer of the internal forces to the 1D objects. If several surface model members connect to each other, these coupling members are generated for each member.

Info

Loads that act in the centroidal axis of the member may be missing in the area of the member openings: When converting into a surface model, all lines in the opening are removed so that no load can be assigned.

In this case, define a force eccentricity at the cross-section for the member load. The load is thus applied realistically at the cross-section edge and is also retained in the surface model.

Tip

In the technical article Application of the member type "surface model", the results of a member model and a surface model are compared.

Stiffness

With this member type, you can use a member with user-defined stiffnesses. The stiffness parameters are to be defined in the 'New member stiffness' dialog (see chapter Member Stiffnesses).

Coupling

A coupling member is a virtual, very stiff member with rigid or hinged member ends. Four options are available for coupling the degrees of freedom of the start and end nodes 'Fixed' or via a 'Hinge'. Couplings allow special situations for force and moment transfers to be modeled. The axial and shear forces or torsional and bending moments are transferred directly from node to node.

Info

The stiffnesses of couplings are applied in relation to the model in order to avoid numerical problems. The same assumptions apply as for members of the rigid member type.

Spring

A spring member offers the possibility to model linear or also nonlinear spring properties with definable effective ranges. For a spring member, you only need to define the member length Lz in the 'Cross-section' tab, no cross-section: The stiffness of the member results from the spring parameters that you define in the 'New member spring' dialog (see chapter Member Springs).

Dashpot

A dashpot basically corresponds to a spring member with the additional property 'damping coefficient'. This member type extends the possibilities for dynamic analyses according to the time history analysis.

As with a spring member, you only need to define the member length Lz in the 'Cross-section' tab, no cross-section. The stiffness of the member results from the spring parameters that you define in the 'New member spring' dialog (see chapter Member Springs). The damping properties can be controlled via the damping coefficient X.

Info

With regard to viscoelasticity, the "dashpot" member type is similar to the Kelvin-Voigt model, which consists of the damping element and an elastic spring (both connected in parallel).

Options

In this section, you can define further member properties using the check boxes.

Nodes on Member

With one or more nodes on the member, you can divide the member into segments without splitting the member (see chapter Nodes).

Connections

The 'Connections' option allows the eccentricities and hinge conditions between members made of angle sections to be modeled, as they occur in trusses or lattice towers.

Info

The check box is accessible if the cross-section of the member consists of an angle section.

You can assign member connections separately to the 'member start i' and the 'member end j'.

Hinges

You can arrange hinges on a member to control the transfer of internal forces at the end nodes (see chapter Member Hinges). For certain member types, the input is locked because internal hinges are already present. You can assign hinges separately to the 'member start i' and the 'member end j'.

Eccentricities

Eccentricities offer the possibility to connect the member eccentrically at the end nodes (see chapter Member Eccentricities). You can assign eccentricities separately to the 'member start i' and the 'member end j'.

Supports

You can assign a support to the member that is effective over its entire length. The degrees of freedom and spring stiffnesses are to be defined in the support conditions (see chapter Member Supports).

Transverse Stiffeners

Transverse stiffeners on the member have an influence on the warping stiffness of the member. They affect the calculation with torsional warping taking seven degrees of freedom into account (see chapter Member Transverse Stiffeners).

Member Openings

Member openings affect the cross-section values and the internal force diagram. They are relevant for the 'surface model' member type. Chapter Member Openings describes how to define the type and position of the openings.

Nonlinearity

You can assign a nonlinearity to the member. The nonlinear properties are to be defined as member nonlinearities (see chapter Member Nonlinearities).

Intermediate Result Points

With intermediate result points, you can control the table output of the results along the member. The division points are to be defined in the 'New member result intermediate point' dialog (see chapter Member Result Intermediate Points).

Info

Intermediate result points have no influence on the determination of the extreme values or the graphical result diagram.

End Modifications

With end modifications, you can graphically adjust the geometry of the member at its ends. This allows protrusions, shortenings, or chamfers to be prepared for the rendered display.

Info

In contrast to member eccentricities, end modifications have no effect on the calculation.

'Lengthening': You can define a 'lengthening' for the member start and the member end. A negative value Δ acts as a shortening.

'Slope': With a slope, you can chamfer each member end. Inclination angles about the two member axes y and z are possible. A positive angle causes a clockwise rotation about the respective positive axis.

Activate Load Transfer

The check box allows the loading of the member – independent of the stiffness of the member – to be distributed by means of a load transfer. Thus, the member is effective in the model through its stiffness. The distribution of the load to the adjacent objects, on the other hand, is controlled by the parameters that you can define in the Load transfer tab.

Deactivate for Calculation

If you tick this check box, the member including loading is not taken into account in the calculation. This allows you to analyze how the load-bearing behavior of the model changes when certain members are not effective. The members do not need to be deleted; the loads are also retained.

Cost Estimation

As a rule, the cost estimation is carried out with the costs of the material that is assigned to the members of a cross-section (see chapter Materials). If specific parameters are to apply to a member, you can define the unit costs and units separately in the 'Cost estimation' tab. The principle corresponds to the procedure described for cross-sections.

Estimation of CO2 Emissions

The estimation of CO2 emissions is also usually based on the material of the cross-section. However, you can also define the unit emissions and units specifically for each member in the 'Estimation of CO2 emissions' tab. The principle is described in chapter Cross-Sections for the emissions of certain cross-sections.

Parent Chapter