The Base tab manages the elementary member parameters. If you select a check box in the 'Options' section, another dialog tab is usually added. There you can define the respective details.
Member Type
The member type controls the way in which internal forces can be absorbed or which properties are assumed for the member. The list offers various member types to choose from.
Beam Member
A beam is a bending-rigid member that can transfer all internal forces. A beam member has no hinges at its member ends. This member type can be loaded by all load types.
Rigid Member
A rigid member couples the displacements of two nodes by a rigid connection. It therefore corresponds in principle to a coupling. This allows you to define members with very high stiffness, taking hinges into account that can also have spring constants and nonlinearities. Numerical problems hardly occur since the stiffnesses are adapted to the system.
Internal forces are output for rigid members if you activate Results for couplings in the Navigator - Results at the bottom of the 'Members' category.
The following stiffnesses are assumed for rigid members:
| Longitudinal stiffness E · A | 1013 · ℓ [SI unit] with ℓ = member length |
| Torsional rigidity G · IT | 1013 · ℓ [SI unit] |
| Bending stiffness E · I | 1013 · ℓ3 [SI unit] |
| Shear stiffness GAy / GAz (if activated) | 1016 · ℓ3 [SI unit] |
Rib Member
Ribs can be used to model T-beams (downstand beams). For this member type, the eccentricities and effective plate widths are taken into account in the FEM model.
Ribs are primarily suitable for reinforced concrete members, since the rib internal forces and cross-sections are included in the Concrete Design. A steel plate with a welded-on "rib" should be modeled as a surface with an eccentrically connected member.
The list offers several options for the 'Rib arrangement'.
As a rule, a rib is an eccentrically arranged member. The eccentricity is automatically determined from half of the surface thickness and half of the member height. However, it can also be defined manually. The eccentricity of the rib increases the stiffness of the model. In a centric arrangement, the centroidal axis of the rib lies in the center of the surface.
The effective widths of the rib are to be defined for the left and right side in the 'Flange dimensions' section. In most cases, the 'Find automatically' setting can be retained, with which the program determines the two surfaces. If more than two surfaces meet at the line of the rib member, the relevant surfaces must be defined manually.
There are various options for entering the integration widths b-y,int and b+y,int (see image New rib): The widths can be entered directly or automatically determined from the member length using the Lref / 6 and Lref / 8 options. They can also be determined according to the specifications of a standard, for example according to 'EC2' Section 5.3.2.1.
The by,int values define the width of the surface or the integration area from which the internal forces are to be integrated. The by,eff values represent the cross-section width of the rib flange from the web center to the respective edge. By default, by,int and by,eff are set equal. However, you can define them separately after clicking the button
.
If nodes of the 'Nodes on member' type have been defined, the rib can be defined section by section for the individual segments. If several segments are defined, the offset width ranges can be linearly connected to each other via the 'Linear distribution' table column in order to prevent large stiffness jumps in the rib member.
For 3D models, the effective widths have no influence on the stiffness, since the increased stiffness is taken into account by the eccentric member. However, the effective widths affect the distribution of the member and surface internal forces.
Truss Member
A truss member corresponds to a beam member with moment hinges at both ends. In addition, the rotation about the longitudinal axis is released at the member start by a hinge φx. For this member type, the bending and torsional moments resulting from the loads on the member are output.
Truss Member (Only N)
This type of truss member with the stiffness E ⋅ A is able to absorb axial forces in the form of tension and compression. Only nodal internal forces are output. The member has a linear internal force diagram unless a concentrated load acts on the member. No moment diagram is output that could result from self-weight or a line load. However, the nodal forces are calculated from the member loads, thereby ensuring correct further transmission.
Buckling-Restrained Brace
The Buckling-restrained brace type enables the modeling of a member with a steel core (flat bar or cross-shaped section) and a concrete-filled casing in a square or round hollow section. It is used particularly in the USA for the bracing of buildings at risk from earthquakes.
The steel core can move within the concrete casing without bonding. Under compression, a "micro-buckling" with high mode shapes occurs, since the casing prevents global buckling of the entire member.
Only the steel core is taken into account for the stiffness of the member; for the automatic self-weight, the concrete casing with the outer steel shell is also included.
Tension Member
A tension member can only absorb tensile forces. The member type corresponds to a 'truss member (only N)' that fails under a compressive force.
The calculation of a structure with tension members is carried out iteratively: In the first step, the internal forces of all members are determined. If tension members receive a negative axial force (compression), another iteration step starts. The stiffness components of these members are no longer taken into account – they have failed. This process is continued until no tension member fails anymore. A system can become unstable due to the failure of tension members.
Compression Member
A compression member can only absorb compressive forces. The member type corresponds to a 'truss member (only N)' that fails under a tensile force. Failing compression members can lead to an unstable system.
Buckling Member
A buckling member corresponds to a 'truss member (only N)' that absorbs tensile forces without limitation, but compressive forces only up to the critical force. For Euler buckling mode 2, this force is determined as follows:
This member type often allows you to circumvent instabilities that arise in a nonlinear calculation according to second- or large deformation analysis due to the buckling of truss members. If these are replaced (realistically) by buckling members, the critical load is increased in many cases.
Cable Member
A cable can only be stressed in tension. This allows cable chains to be analyzed using an iterative calculation according to large deformation analysis, taking longitudinal and transversal forces into account.
Cables are suitable for models in which large deformations can occur with corresponding changes in internal forces. For simple guy wires such as those on a canopy, tension members are completely sufficient.
Reinforcement Bar
This member type allows you to model reinforcing steel bars in the FE model of a reinforced concrete element. For example, discontinuity regions based on the truss analogy can be analyzed (tie and compression strut for consoles, beams with openings).
The reinforcement bar has an automatic connection function to other elements such as members or surfaces if it is physically located within the element. Like the truss member (only N), a reinforcement bar only has a tangential stiffness. Nonlinear material behavior is not yet possible at present.
In the 'Settings' section, a reinforcing bar is set as the member type. Further reinforcement bar types are available if the Tendons add-on is activated.
In the 'Master objects' section, assign the members or surfaces in which the reinforcement bar is located. Use the button
for this. Then you can use the button
to connect the reinforcement bar automatically to the master object.
Cable on Pulleys
This cable member type also only absorbs tensile forces and is calculated according to cable theory (large deformation analysis). However, a cable member on pulleys can only be defined on a polyline that lies in a plane and has at least three nodes. This member type is suitable for flexible tension elements whose longitudinal forces are routed through the model via deflection points. An example application is a pulley system.
In contrast to a normal cable member, only a displacement in the longitudinal direction (ux) is possible in the inner nodes. Therefore, the member must not be loaded by member loads acting in the local y or z direction. Only displacements ux and axial forces N are taken into account.
At the inner nodes of the polyline, it does not matter whether a nodal support is present or whether the member is connected to another structure: The global structure of the cable member is analyzed over the length of the polyline.
In the 'Pulleys' tab, you can define the further parameters such as deflection nodes and the properties of the pulley wheels.
The table allows you to arrange pulleys at one or more nodes of the cable. The 'Generate at nodes' list contains all nodes used when defining the polyline. In the 'Pulley Wheel' column, you can select an already defined type for pulleys or define a new one.
From these specifications, the program creates nodes on the edge of the pulley wheel, cable members to these nodes, and rigid members for the connection to the node of the polyline.
Result Beam
The result beam is suitable for integrating surface, solid, or member results in a fictitious member. For example, this allows you to read the resulting shear forces of a surface for the masonry design.
The line of a result beam can be placed anywhere in the model. The result beam requires neither a support nor a connection to the model. However, a cross-section must be assigned in order to enable a design. No loads can be applied to a result beam.
In the 'Integrate stresses and forces' section, select the type of result beam to define the geometric shape of the integration area. In the 'Parameters' section, you can then define the dimensions. They are related to the member line at its center of gravity.
In the 'Include objects' section, define the surfaces, surface cells, solids, and members whose results are to be taken into account during the integration. Alternatively, select 'All' objects and then exclude certain elements in the 'Excluded from inclusive objects' section.
Result Line
The result line is suitable for integrating surface, solid, or member results in a line. This line can be placed anywhere in the model.
The principle corresponds to a result beam. However, you do not need to assign a cross-section. In the 'Cross-section' tab, you can read the length of the line and, if necessary, rotate the line for the result display; it has no further function.
Load Transfer
This member type allows you to apply loads to objects that are connected to the member at end or intermediate nodes. The member itself has no stiffness. You can define the criteria for the load transfer in a new tab.
The load transfer is currently carried out using the strip method. The load on the load transfer member – member load or nodal load of the type force, moment, or mass – is transferred proportionally to the nearest common structural objects. These are, for example, supported nodes, members, nodes of surfaces, or supported lines.
If the self-weight of the member is to be taken into account, you can define the member weight in the 'Parameters' section.
In the 'Loaded objects' section, the numbers of the nodes are specified at which the member load is transferred to the adjacent objects. If not all of these nodes are relevant, you can exclude certain nodes in the 'Without effect on' section.
Virtual Joist
This member type allows you to apply the cross-section properties for Open Web Steel Joists that the Steel Joist Institute has stored in so-called "Virtual Joist" tables. These Virtual Joist sections represent equivalent wide flange beams that come very close to the top chord area, the effective moment of inertia, and the weight. The girder is thus replaced by a member with a virtual section. This allows you to simulate complex load-bearing units such as a truss girder in the global structure.
In the list, select the 'Series' of the virtual joist.
In the 'Virtual joist' list, you can then define the exact type.
The button
in the 'Cross-section and material' section allows you to import the virtual joist from the cross-section library.
Composite Beam
This member type allows you to model individual partial cross-sections as separate members and connect them to each other by rigid couplings. The composite behavior can be modeled as shear-rigid, shear-soft, or semi-rigid. A corresponding fastener library is planned for a future extension.
The definition of the composite cross-section is currently only carried out in RSECTION (see chapter Base of the RSECTION manual). The composite cross-sections already contained in the cross-section library will be transferred to the new concept at a later point in time and will thus also be usable. A uniform workflow for the design of the individual partial cross-sections is also planned for the future. However, the partial cross-sections can already be verified in the associated design add-ons.
Surface Model
This member type is primarily suitable for modeling castellated beams with openings or local cross-section reductions such as openings for supply lines in the member model. The member is converted into a surface model in which the member openings are arranged according to the user specification. However, the member is retained. The following prerequisites must be met:
- The cross-section is a standard or parametrized thin-walled cross-section with a web.
- The material of the cross-section is based on an isotropic linear-elastic material model.
For the 'surface model' member type, the member is present both as a member and as a surface object. The geometric properties are identical; both models have the same center of gravity. The display is controlled in the Navigator - Display via the entry Model → Base objects → Members → Surface model or the button
in the toolbar.
The FE mesh of the surface model is generated automatically; it cannot currently be influenced. The surface model is used for the structural analysis. For the evaluation, both the member results (as for a result beam, where the stresses of the member partial surfaces are integrated into member internal forces) and the surface results are available. The control can also be carried out here via the Navigator - Display or the button
.
The design of a surface model member in the add-ons is carried out with the member internal forces and the member cross-section.
As can be seen in the image above, several rigid members are created at the member ends of a surface model member. They connect the surface model to the end nodes of the adjacent members. This ensures the correct transmission of the internal forces to the 1D objects. If several surface model members connect to each other, these coupling members are created for each member.
In this case, define a force eccentricity at the cross-section for the member load. The load is thus applied realistically at the edge of the cross-section and is retained in the surface model.
Stiffness
With this member type, you can use a member with user-defined stiffnesses. The stiffness parameters are to be defined in the 'New member stiffness' dialog (see chapter Member Stiffnesses).
Coupling
A coupling member is a virtual, very stiff member with rigid or hinged member ends. Four options are available for coupling the degrees of freedom of the start and end nodes 'Fixed' or via a 'Hinge'. Couplings allow you to model special situations for force and moment transfers. The axial and shear forces or torsional and bending moments are transmitted directly from node to node.
Spring
A spring member offers the possibility to model linear or nonlinear spring properties with definable effective ranges. For a spring member, you only need to define the member length Lz in the 'Cross-section' tab, not a cross-section: The stiffness of the member results from the spring parameters that you define in the 'New member spring' dialog (see chapter Member Springs).
Dashpot
In principle, a dashpot corresponds to a spring member with the additional property 'Damping coefficient'. This member type expands the possibilities for dynamic analyses according to the time history analysis.
As with a spring member, you only need to define the member length Lz in the 'Cross-section' tab, not a cross-section. The stiffness of the member results from the spring parameters that you define in the 'New member spring' dialog (see chapter Member Springs). You can control the damping properties via the damping coefficient X.
Options
In this section, you can define further member properties using the check boxes.
Nodes on Member
With one or more nodes on the member, you can divide the member into segments without splitting the member (see chapter Nodes).
Hinges
You can arrange hinges on a member to control the transfer of internal forces at the end nodes (see chapter Member Hinges). For certain member types, the input is locked because internal hinges are already present. You can assign hinges separately to the 'Member start i' and the 'Member end j'.
Eccentricities
Eccentricities offer the possibility to connect the member eccentrically at the end nodes (see chapter Member Eccentricities). You can assign eccentricities separately to the 'Member start i' and the 'Member end j'.
Supports
You can assign a support to the member that is effective over its entire length. The degrees of freedom and spring stiffnesses are to be defined for the support conditions (see chapter Member Supports).
Transverse Stiffeners
Transverse stiffeners on the member have an influence on the warping stiffness of the member. They affect the calculation with torsional warping taking seven degrees of freedom into account (see chapter Member Transverse Stiffeners).
Member Openings
Member openings affect the cross-section values and the internal force diagram. They are relevant for the 'surface model' member type. Chapter Member Openings describes how you can define the type and position of the openings.
Nonlinearity
You can assign a nonlinearity to the member. The nonlinear properties are to be defined as member nonlinearities (see chapter Member Nonlinearities).
Intermediate Result Points
With intermediate result points, you can control the table output of the results along the member. The division points are to be defined in the 'New member intermediate result point' dialog (see chapter Member Intermediate Result Points).
End Modifications
With end modifications, you can graphically adjust the geometry of the member at its ends. This allows you to prepare protrusions, shortenings, or chamfers for the rendered display.
'Protrusion': You can define a 'Protrusion' for the member start and the member end. A negative value Δ acts as a shortening.
'Slope': With a slope, you can chamfer each member end. Inclination angles about the two member axes y and z are possible. A positive angle causes a clockwise rotation about the respective positive axis.
Activate Load Transfer
The check box allows you to distribute the load on the member – regardless of the stiffness of the member – using a load transfer. The member is thus effective in the model through its stiffness. The distribution of the load to the neighboring objects, however, is controlled by the parameters that you can define in the load transfer tab.
Deactivate for Calculation
If you select this check box, the member including loads is not taken into account in the calculation. This allows you to analyze how the structural behavior of the model changes when certain members are not effective. The members do not need to be deleted; the loads are also retained.
Cost Estimation
The cost estimation is usually carried out with the costs of the material that is assigned to the members of a cross-section (see chapter Materials). If specific parameters are to apply for a member, you can define the unit costs and units separately in the 'Cost estimation' tab. The principle corresponds to the procedure described for cross-sections.
Estimation of CO2 Emissions
The estimation of CO2 emissions is also usually based on the material of the cross-section. However, you can define the unit emissions and units specifically for each member in the 'Estimation of CO2 emissions' tab. The principle is described in chapter Cross-Sections for the emissions of certain cross-sections.